Hitachi 7080 Clinical Automatic Chemistry Biochemistry Analyzer

Short Description:

7080 biochemical analyzer can be used for chemical analysis, urine examination, immunological examination and so on with serum, urine and cerebrospinal fluid as samples, and 36 kinds of items can be detected at the same time. The analysis speed is up to 360 test/hour. At the same time, the device can simultaneously meet the needs of 4 reagents for project testing, and can carry out unconventional project testing as required.

 

Test items:

Blood biochemical examination: including liver function, kidney function, blood lipid, blood glucose, serum protein, etc.

Immunological examination: including immunoglobulin, apolipoprotein complement, etc.

Non-routine item detection.


Product Detail

Product Tags

1
2
3

Performance characteristics

Homo sapiens 7080:
New:
New modeling: streamlined profile, transparent cover. Keeping the working environment quiet and convenient for observing the working status
New technology: a new optical system with a radiopaque coating with increased light input is adopted.
The WinNT platform is used ubiquitously and combined with a Hitachi window of view interface to give a fresh look.
New materials: a new reaction cup was adopted, and a new loading apparatus was used. Sample volume (increase / decrease) 2 ~ 25 UL adjustable, 0.1 UL step.
Reagent reaction volumes up to a minimum of 150ul / test.
Ling:
Methods are flexible: up to 20 analytical methods are available, and the analytical range covers blood, urine and immune responses, special project examination,
All assays had an anterior band check
Versatile sample trays: both plain tubes and micro sample cups suitable for use with pediatric patients are available.
Choice flexible: reaction times flexible. It can be set at 3, 4, 5, 10, 15 / 22 min depending on the different items.
Wide range of applications.
Multi reagent optional, two reagent assay items there can be three options for the time of addition of the second reagent,
Flexible application when setting experimental parameters, with an increased range of select reagents.
Standards and samples were automatically pre diluted, addressing the problem of multi-point correction with only one concentration standard,
Also addressed high value samples, urine samples were automatically diluted. The same item allows simultaneous serum infusion
And urine as two sets of parameters (not occupying reagent channels), where users can pool general samples and needs at the time of assay
The pre diluted samples were assayed together for convenient and flexible application.
Run sensitive: the aspirator uses a precision needle tip to grind slants and sample volume tracking techniques, as well as an extremely fine
Needle tip construction, which guarantees a minimum contact area between the needle tip and the sample, minimizes contamination carryover.
The quantity tracking technique guarantees the acquisition of a trace amount of sample, with the needle tip decreasing as the liquid level of the sample drops
To guarantee the ability to aspirate to an adequate set amount.
The sample needle has a two-way release collision function.
Dexterity:
Dexterous design: humanized design. Cover front wrench, faecal handling. The sample tray half cover design facilitates the addition of samples while
There is no need to cover.
Dexterous fabrication: total reaction process monitoring. The parameters were set with absorbance limit check and linearity check.
Three conditions alarm for high value or abnormal samples and allow automated review of stock, reduced, increased, or diluted amounts.
Dexterous run: the user can select a series of maintenance items (cup blank assay, luminometer check, etc.) that the instrument can execute automatically
Yi:
Short operation: intelligent for emergency operations, users simply place their samples onto a location specified in the operation interface,
Instruments can be completed automatically without special training by clicking the emergency key.
Emergency outcomes single item delivery.
Operator login permissions are set to guarantee secure use of the instrument and confidentiality of patient information,
And compliance with standardized operating procedures.
7080 application windows NT software implements the online help function and users can always operate on the operation screen
On being assisted by a detailed explanation without having to turn over the operating instructions, the convenience is greatly improved.
Jing:
1. Since the cyclic constant temperature water bath is used to control the temperature, the control temperature accuracy can reach 37 ° C ± 0. 1℃。 The hollow no contact suction mechanism is designed, the whole pipe of the suction pipette is filled with degassed water, the outer needle body and the inner core are not in contact, this makes the inner wall of the needle body never wear, the middle inner core uses space ceramic material (wear, high temperature resistance). Thus, the instrument does not degrade in suction accuracy, either when it is new or after several years of high workload testing. Together with sophisticated digital stepping motor control technology, its accuracy can reach 0.1ul/step.
2. The patented design of a plate-shaped streamlined design with a Teflon coating on the outside, this design makes the stir bar have a small surface area, adequate stirring effect, easy rinsing, and small cross contamination.
Standard specifications
Project content
Processing capacity maximum 720 tests / hour (including ISE)
A maximum of 49 items (including ISE) were analyzed simultaneously
Analytical end points, 2-point method, rate method, etc.20
Sample size ranged from 2 to 25 μ L / test, which can be adjusted to 0.1 μ L-unit increase
Reagents 1-4 reagents, 20-270 each μ L / test (1 μ L unit),
Mm final reagent volume 150-320 μ L / test
The sample tray standard sample (50), emergency sample (20), management sample (8),
Standard (34), wash solution (3)
Sample cup Hitachi standard sample cup, Hitachi microsample cup, original blood collection vessel
Vials 7, 20, 70 ml (same as 7170)
Reagent reservoirs include 33 positions each at R1 and R2 for a total of 66 reagent positions All reagents were stored cold
Reaction disk turntable
Reaction cups were made of Hitachi UV plastic and used semi permanently (5 mm light path length)
Reaction times 3, 4, 5, 10, 15 min (can be set for each item)
Reaction temperature 37 ° C ± 0.1 ° C
Complete stirring takes place immediately after stirring to raise each reagent
The test wavelength was 340-800 nm (fixed at 12
Test methods single wavelength or dual wavelength simultaneous test
Data processing function item selection, auto calibration, multi-point calibration, line calibration
Calibration point selection function, colorimetric analysis operation, rate analysis operation
Isoenzyme analysis, serum information, sample blank compensation, inter item operations
Real time QC, X-R management, automatic re inspection, calibration tracking
Test calculations, data storage (common sample, ≥ 10000 total samples)
Report form printing analysis results (surveillance mode, multiple reporting modes), worksheet, recheck list
Calibration report, photometer confirmation list, QC list, alarm trace
Reaction process printing, check quantity printing, run information management printing
Support for functional reproducibility computing, sleep patterns, emergency & easy analysis features, information management at operation
Set by sample type, per project host transfer feature, operator ID management feature
Online help features, remote maintenance features (optional)
Hard disk of secondary memory unit
Print format needle punches 80 lines
Display color display
System interface RS232C
Setting up conditions
Project content
Power supply AC220 ± 10%, 50 / 60 Hz,
Electricity consumption 2.0 KVA
Type 3 grounding (type C specified by the electrical worker)
Standard surrounding temperature 15-32 ℃ (measured at ± 2 ℃)
Standard ambient humidity 45-85%
Water pressure in ion exchange apparatus (49-343 kPa)
The drain opening was 50 mm in diameter and 100 mm in height

Standard specifications

Processing capacity maximum 720 tests / hour (including ISE)
A maximum of 49 items (including ISE) were analyzed simultaneously
Analytical end points, 2-point method, rate method, etc.20
Sample size ranged from 2 to 25 μ L / test, which can be adjusted to 0.1 μ L-unit increase
Reagents 1-4 reagents, 20-270 each μ L / test (1 μ L unit),
Mm final reagent volume 150-320 μ L / test
The sample tray standard sample (50), emergency sample (20), management sample (8),
Standard (34), wash solution (3)
Sample cup Hitachi standard sample cup, Hitachi microsample cup, original blood collection vessel
Vials 7, 20, 70 ml (same as 7170)
Reagent reservoirs include 33 positions each at R1 and R2 for a total of 66 reagent positions All reagents were stored cold
Reaction disk turntable
Reaction cups were made of Hitachi UV plastic and used semi permanently (5 mm light path length)
Reaction times 3, 4, 5, 10, 15 min (can be set for each item)
Reaction temperature 37 ° C ± 0.1 ° C
Complete stirring takes place immediately after stirring to raise each reagent
The test wavelength was 340-800 nm (fixed at 12
Test methods single wavelength or dual wavelength simultaneous test
Data processing function item selection, auto calibration, multi-point calibration, line calibration
Calibration point selection function, colorimetric analysis operation, rate analysis operation
Isoenzyme analysis, serum information, sample blank compensation, inter item operations
Real time QC, X-R management, automatic re inspection, calibration tracking
Test calculations, data storage (common sample, ≥ 10000 total samples)
Report form printing analysis results (surveillance mode, multiple reporting modes), worksheet, recheck list
Calibration report, photometer confirmation list, QC list, alarm trace
Reaction process printing, check quantity printing, run information management printing
Support for functional reproducibility computing, sleep patterns, emergency & easy analysis features, information management at operation
Set by sample type, per project host transfer feature, operator ID management feature
Online help features, remote maintenance features (optional)
Hard disk of secondary memory unit
Print format needle punches 80 lines
Display color display
System interface RS232C

Setting up conditions

Power supply AC220 ± 10%, 50 / 60 Hz,
Electricity consumption 2.0 KVA
Type 3 grounding (type C specified by the electrical worker)
Standard surrounding temperature 15-32 ℃ (measured at ± 2 ℃)
Standard ambient humidity 45-85%
Water pressure in ion exchange apparatus (49-343 kPa)
The drain opening was 50 mm in diameter and 100 mm in height